Professional repair and regeneration of MRI gradient amplifiers, CT high-voltage generators, DSA angiograph modules and premium ultrasound beamformers. Save up to 92% vs OEM replacement. Fast turnaround 3–10 business days. Acore – Knurow, Poland.
Medical Electronics Repair – MRI, CT Scanner, DSA Angiograph, Ultrasound
Medical imaging equipment contains some of the most expensive and complex electronics in existence. A new MRI gradient amplifier costs 80,000–250,000 EUR. A CT high-voltage generator: 40,000–120,000 EUR. Yet 70–85% of electronic failures in these systems are repairable at a fraction of the cost. Acore specializes in component-level repair of medical imaging electronics, delivering repaired modules with performance matching OEM specifications.
Why Hospitals Choose Repair Over Replacement
OEM lead times of 6–20 weeks – every day of downtime costs 6,000–30,000 PLN in lost revenue
OEM spare part prices – manufacturers charge 40–60% of total system value for key modules
Service contract alternative – annual OEM contracts cost 8–20% of equipment value; targeted repair is 5–15x cheaper
MRI Modules We Repair
Module
Brands
Common Faults
Repair Price
New Part Price
Gradient Amplifier
Siemens Magnetom, GE Signa, Philips Ingenia
Failed IGBT, DSP fault, shunt resistor damage
5,000–18,000 PLN
80,000–250,000 EUR
RF Power Amplifier
Siemens Aera/Vida, GE Discovery, Philips Achieva
LDMOS failure, power feedback error, circulator fault
Component replacement – original or equivalent certified parts only
4-hour functional load test with parameter logging
Repair certificate with before/after measurements – 12 months warranty
FAQ
Can you repair a Siemens Magnetom gradient amplifier without recalibrating the whole scanner?
Yes – we supply a pre-calibrated exchange module. For Siemens Magnetom systems only shim calibration (30–90 min) is needed after GCC replacement, performed by your in-house physicist or service engineer.
Does third-party electronic repair require MDR recertification?
Repair of an individual module (not the complete medical device) does not require MDR recertification provided post-repair parameters match OEM specification. We issue a full measurement-documented repair certificate.
What is the turnaround time?
Standard: 5–10 business days from receipt. Priority service (2–4 days) available for contracted customers. Exchange unit available for MRI gradient amps and CT HV generators.
Do you repair GE Revolution CT HV generators?
Yes – Revolution EVO and Apex HV generators, DAS modules, X-ray tube control boards. Diagnosis and quote within 48 hours of receiving the module.